BH GSO ASTM D4718/D4718M:2023 Scope

1.1 This practice presents a procedure for calculating the unit weights and water contents of soils containing oversize particles when the data are known for the soil fraction with the oversize particles removed. 1.2 This practice also can be used to calculate the unit weights and water contents of soil fractions when the data are known for the total soil sample containing oversize particles. 1.3 This practice is based on tests performed on soils and soil-rock mixtures in which the portion considered oversize is that fraction of the material retained on the 4.75-mm [No. 4] sieve. Based on these tests, this practice is applicable to soils and soil-rock mixtures in which up to 40 % of the material is retained on the 4.75-mm [No. 4] sieve. The practice also is considered valid when the oversize fraction is that portion retained on some other sieve, but the limiting percentage of oversize particles for which the correction is valid may be lower. However, the practice is considered valid for materials having up to 30 % oversize particles when the oversize fraction is that portion retained on the 19-mm [3⁄4-in.] sieve. 1.4 The factor controlling the maximum permissible percentage of oversize particles is whether interference between the oversize particles affects the unit weight of the finer fraction. For some gradations, this interference may begin to occur at lower percentages of oversize particles, so the limiting percentage must be lower for these materials to avoid inaccuracies in the computed correction. The person or agency using this practice shall determine whether a lower percentage is to be used. 1.5 This practice may be applied to soils with any percentage of oversize particles subject to the limitations given in 1.3 and 1.4. However, the correction may not be of practical significance for soils with only small percentages of oversize particles. The person or agency specifying this practice shall specify a minimum percentage of oversize particles below which the practice need not be applied. If a minimum percentage is not specified, 5 % shall be used.

Best Sellers From Construction and Building Sector

GSO 1431:2002
 
Gulf Technical Regulation
Sanitary appliances - pressurized flushing devices
GSO 1427:2008
 
Gulf Standard
Ceramic Sanitary Appliances - Western Water Closets
GSO 2084:2010
 
Gulf Standard
Design and application of speed control humps
GSO 1421:2002
 
Gulf Technical Regulation
Hollow blocks made from clay for walls

Recently Published from Construction and Building Sector

GSO EN 933-2:2024
EN 933-2:2020 
Gulf Standard
Tests for geometrical properties of aggregates - Part 2: Determination of particle size distribution - Test sieves, nominal size of apertures
GSO EN 933-4:2024
EN 933-4:2008 
Gulf Standard
Tests for geometrical properties of aggregates - Part 4: Determination of particle shape - Shape index
GSO ASTM F1861:2024
ASTM F1861:21 
Gulf Standard
Standard Specification for Resilient Wall Base
GSO ASTM C880/C880M:2024
ASTM C880/C880M:23 
Gulf Standard
Standard Test Method for Flexural Strength of Dimension Stone